⚡ Middle East's premier earthing & lightning protection partner
Engineering Services

Engineers in the field. Physics on your side.

Eight engineering disciplines, one team. From a 30-minute ground-resistance sanity check to a forensic investigation of a transformer fire — we bring calibrated instruments, signed certificates, and no spin.

Service 01

Electrical Safety Audit (ESA)

A structured, end-to-end review of every element in your facility that carries, switches or distributes power — and everything it's supposed to protect. Benchmarked against IEC 60364, IS 732, IS 3043, NFPA 70E and local regulatory authority codes.

  • Visual & thermographic survey of switchgear, DBs, cables and terminations
  • Earth-continuity, insulation-resistance and earth-loop impedance testing
  • Arc-flash hazard calculation and PPE category classification
  • Risk rating, prioritised remediation roadmap, compliance gap analysis
  • Signed audit report accepted by insurers, QHSE auditors and authorities
Book an ESA
Certified Auditors Electrical Safety Audit
Service 02

Electrical Failure Analysis

Fires, flashovers, exploded transformers, mysteriously dead IT racks — our forensic investigators have seen it all. We treat every incident as a scientific inquiry, using thermal imaging, oscilloscope capture, insulation diagnostics and metallurgical analysis to trace the root cause and prevent recurrence.

  • 🔎Site walk-through, sample retrieval, witness interviews
  • 🔎Thermography, PD (partial discharge) analysis, DGA on transformer oil
  • 🔎Insurance-grade cause-and-effect report with photographic evidence
  • 🔎Recommended corrective action, design changes, training inputs
  • 🔎Expert witness support for arbitration or litigation
Investigate an incident
Forensic Grade Electrical Failure Analysis
Service 03

Data Centre Earthing

The Middle East is the fastest-growing hyperscale DC region on earth. A single nanosecond of earth-potential rise can crash a Tier-III facility; a single high-impedance bond can put an entire data hall off-line. Our DC earthing practice covers everything from Signal Reference Grid design to TN-S isolation.

  • 🖥Signal Reference Grid (SRG) design, mesh-bonding & equipotentialisation
  • 🖥TN-S isolation, clean-earth vs. dirty-earth segregation, HRG design
  • 🖥Low-inductance copper bus-bars, compression terminations, test links
  • 🖥Coordinated Type 1+2+3 SPDs aligned to UPS, static switch and PDU
  • 🖥Full Tier III/IV commissioning test pack, fault-loop recordings
Tier III / IV Data Center Earthing
Service 04

Lightning Protection Survey

Every Lightning Protection System we design starts with a proper IEC 62305-2 risk assessment. We calculate annual strike frequency (Nd), tolerable loss (RT), and arrive at the correct Level of Protection (LPL) — because over-designed LPS wastes money and under-designed LPS kills people.

  • Ng lightning flash density mapping (ISO 31000 + GIS data)
  • Risk components R1–R4 (loss of life, public service, cultural, economic)
  • Protection-zone layout — rolling sphere, mesh and protection-angle method
  • ESE radius simulation & strike-capture probability mapping
  • Signed design dossier stamped by a competent engineer
IEC 62305-2 Lightning Protection Survey
Service 05

Earthing Audit

An earthing system is only as good as its measured impedance on the day of the test. Our earthing audit gives you a calibrated, date-stamped, legally defensible record of your ground system's actual performance — not its design intent.

  • 🌍3-pin fall-of-potential & 62% rule earth resistance measurement
  • 🌍Clamp-on (ART) testing for bonded grids without disconnection
  • 🌍Wenner & Schlumberger soil resistivity profiles (0.5 m – 30 m)
  • 🌍Earth-bond continuity, step-and-touch voltage gradient mapping
  • 🌍NABL-calibrated instruments, signed test certificates, remediation plan
NABL Traceable Earthing Audit
Service 06

Electromagnetic Field Survey

Power-frequency (50/60 Hz) and radio-frequency electromagnetic fields are invisible — but ICNIRP exposure limits, OSHA regulations and ISO/IEC compliance don't care. We map your facility's EM environment with broad-band and selective meters, compare against exposure limits, and design shielding where required.

  • 📡Power-frequency E-field & B-field mapping (0–300 Hz)
  • 📡RF / microwave survey (100 kHz–60 GHz)
  • 📡ICNIRP / IEEE exposure limit compliance assessment
  • 📡Shielding material selection (mu-metal, conductive films, bonded grids)
  • 📡Full site heat-map with remediation priority
ICNIRP Compliant EM Field Survey
Service 07

EMI / EMC Solutions

Electromagnetic Interference kills sensitive equipment long before you notice. Dropped communications, unexplained trips, test-bench variability — we trace the source (conducted or radiated), engineer the mitigation (filters, shielding, bonding, separation) and verify compliance against IEC/CISPR standards.

  • 🛰Conducted & radiated emission measurements (CISPR 11 / 22 / 32)
  • 🛰Immunity / susceptibility testing (IEC 61000-4 series)
  • 🛰Filter, ferrite and shielded-cable selection & specification
  • 🛰Signal-integrity analysis, common-mode choke design
  • 🛰Pre-compliance testing for CE / UL / KUCAS certification
CISPR / IEC 61000 EMI EMC Solutions
Service 08

Earthing & Lightning Installation

A perfect design on paper means nothing if the trench is shallow, the exothermic weld is under-packed or the down conductor is routed through a re-bar cage. Our crews are CAPE-trained, PQ-certified and equipped to deliver complete LPS and earthing systems from pit to peak — with full commissioning test packs handed over at closeout.

  • 🛠Civil trenching, rock-breaking and borehole drilling for deep electrodes
  • 🛠Exothermic welding, compression lugs, test-link fabrication
  • 🛠Down-conductor and air-terminal mounting, roof penetration detailing
  • 🛠SPD installation, coordinated-protection commissioning
  • 🛠As-built drawings, final earth-resistance certificates, AMC handover
Request installation quote
Turnkey Earthing Installation
How we deliver

From brief to bonded site, in four stages.

01

Scope

Site walk-through, soil resistivity & risk assessment to IEC 62305-2 + local authority codes.

02

Design

CAD drawings, earth-grid simulation (CYMGRD / ETAP), BOQ & Level-of-Protection justification.

03

Deploy

Cape-Electric components from regional stock; commissioning by certified installers.

04

Defend

Annual audits, SPD health checks and reactive support under AMC — for life of asset.

Ready for a real engineer?

Talk to us before your next commissioning.

Whether you're specifying a new site, chasing compliance on an old one, or just want a second opinion on a design — we'll give you one straight answer in plain English.

🛡 IEC certified
📐 PE-stamped reports